Plasmon LF 6602 DVD Player User Manual


 
97654438 E
Page 33
INSTALLATION
INSTALLATION REQUIREMENTS
The LF 6602 is shipped as a complete assembly, ready for cable connection and power up. No tools are
required for the basic installation.
CAUTION
Remove the foam shipping block from each of the shuttle assemblies
before powering on the LF 6600 drives.
Ensure that the internal temperature within the cabinet does not exceed the operating limits as described
in the Product Specification (P/N 97653977) and this document.
The LF 6602 must be connected to a power distribution system that has a direct connection to earth
ground (Terminated Terra [TT] network/ground connected). This unit is not suitable for use on a floating
ground (Interrupted Terra [IT] network). Ensure the drive is connected to a power distribution system with
an adequate current-handling capacity.
Before you install the LF 6602, provide for the clearances as listed in the table below to ensure that future
servicing can be performed safely and to properly ventilate the LF 6602. Clearances are also necessary to
provide operator access to the DOC panels and to the media access doors for loading and unloading
media.
Operational Clearances for LF 6602
Ensure that the site selected for the LF 6602 is able to support a volumetric air flow of 6.4 m
3
/min
(224 cfm). Also, ensure that the operating environment is free from dust and particulates, such as tobacco
smoke.
AREA CLEARANCE
Front 51 cm (20 in)
Rear 51 cm (20 in)
Sides 12.7 cm (5 in)