Runco XP-50 Flat Panel Television User Manual


 
Serial Communications
58 CinemaWall Installation/Operation Manual
P
RELI
M
INARY
IMS:PC1 49 4D 53 3A 50 43 31 Input select = PC1 (Main Picture
when PIP mode)
IMS:SL1A 49 4D 53 3A 53 4C 31 41 Input select = SLOT1A (Main Pic-
ture when PIP mode)
IMS:SL1B 49 4D 53 3A 53 4C 31 42 Input select = SLOT1B (Main Pic-
ture when PIP mode)
IMS:SL2A 49 4D 53 3A 53 4C 32 41 Input select = SLOT2A (Main Pic-
ture when PIP mode)
IMS:SL2B 49 4D 53 3A 53 4C 32 42 Input select = SLOT2B (Main Pic-
ture when PIP mode)
IMS:SL3 49 4D 53 3A 53 4C 33 Input select = SLOT3 (Main Pic-
ture when PIP mode)
ISS:PC1 49 53 53 3A 50 43 31 Sub Picture Input Select = PC1
ISS:SL1A 49 53 53 3A 53 4C 31 41 Sub Picture Input Select =
SLOT1A
ISS:SL1B 49 53 53 3A 53 4C 31 42 Sub Picture Input Select =
SLOT1B
ISS:SL2A 49 53 53 3A 53 4C 32 41 Sub Picture Input Select =
SLOT2A
ISS:SL2B 49 53 53 3A 53 4C 32 42 Sub Picture Input Select =
SLOT2B
ISS:SL3 49 53 53 3A 53 4C 33 Sub Picture Input Select = SLOT3
OSP:OSD0 4F 53 50 3A 4F 53 44 30 OSD OFF
OSP:OSD1 4F 53 50 3A 4F 53 44 31 OSD ON
OSP:RCM0
OSP:RCM1
OSP:RCM2
OSP:RCM3
4F 53 50 3A 52 43 4D 30
4F 53 50 3A 52 43 4D 31
4F 53 50 3A 52 43 4D 32
4F 53 50 3A 52 43 4D 33
Remote Control User Level = Off
Remote Control User Level =
User1
Remote Control User Level =
User2
Remote Control User Level =
User3
OSP:SCR0 4F 53 50 3A 53 43 52 30 Screen Saver SCROLLING BAR
ONLY = OFF
OSP:SCR1 4F 53 50 3A 53 43 52 31 Screen Saver SCROLLING BAR
ONLY = ON
POF 50 4F 46 Power OFF
PON 50 4F 4E Power ON
SSC:0000 53 53 43 3A 30 30 30 30 Screen Saver Duration = 0:00
(Interval Mode) or Finish Time =
0:00 (Time of Day Mode)
Table 6-1. Serial Commands (continued)
ASCII Hex Description