Trimble Outdoors AcutimeTM2000 Synchronization Kit TV Antenna User Manual


 
Acutime 2000 Synchronization Kit User Guide 5-19
5 System Operation
The survey operating dimension can be set to auto and 2D if segments
are saved (8E-26) while a survey is in process. The receiver uses the
dimension setting saved for the next survey. If a reference altitude has
been entered and the receiver is set to 2D survey, the reference
altitude is used. If a reference altitude has not been entered and the
receiver is set to 2D survey, an altitude of 0 is used for 2D survey (not
recommended).
Table 5-7 Self-Survey Configuration (segment 7)
Parameter Factory default Set Request Report
Survey enable flag TRUE 8E-A6 8E-A6 8F-A6
Survey length 2000 8E-A6 8E-A6 8F-A6
Survey save flag FALSE 8E-A6 8E-A6 8F-A6
Survey operating
dimension
Full Position 3D 0xBB 0xBB 0xBB
Table 5-8 NMEA Configuration (segment 8)
Parameter Factory default Set Request Report
NMEA message mask 0x00000020 (ZDA) 7A 7A 7A
NMEA message rate 1 7A 7A 7A
NMEA options 0 7A 7A 7A
Table 5-9 UTC Information (segment 11)
Parameter Factory default Set Request Report
have_utc FALSE