AVerMedia Technologies EB5416DVD DVD Player User Manual


 
59
- START
Setup daylight start up date and time.
- END
Setup daylight stop date and time.
- TIME OFFSET
Assign a time that it is for daylight saving time offset in your time zone. For example: if the
time zone is in U.S. Eastern, the time offset is 1 hour.
(5) TEMPERATURE
Set the DVR unit temperature type and high/low threshold limit.
- TEMPERATURE FORMAT:
Temperature pattern display on front LED panel.
- HIGH THRESHOLD:
Set a specific temperature limited (0 ~ 100°C) for fan active. When the hard disk
temperature is higher than limited temperature, the fan will be active. The default value is
35°C.
- LOW THRESHOLD:
Set a specific temperature limited (0 ~ 30°C) for fan stop. When the hard disk temperature is
lower than limited temperature, the fan will be stop. The default value is 30°C.
- DVR HOT PROTECT:
Set the temperature limit to shutdown hard disk when the DVR unit temperature is higher
than (>) limited (55 ~ 70°C).
8.1.1.2 Camera Setup
(1)
(2)
(3)
(4)
(5)
(1) Camera icon
Select the camera that user wants to set up.
(2) Camera Title
Enter a name for the camera
(3) Network Audio Enable
Enable/disable the audio sound record when recording the video through network.
(4) Video Adjustment
Select the camera and adjust the Brightness, Contrast, Hue and Saturation of the selected
camera. Click Default Value to set all video setting back to the default.