Ciprico 4400 Universal Remote User Manual


 
Operations MediaVault 4440 User Manual
5-14
MV 4440_Ciprico Inc.
Mode Set Button
This is a multi-function button. It can be used to:
Change the mode (RAID level).
Mute the audible alarm.
Start a rebuild process, if the MV 4440 is in RAID 6 mode.
NOTE: If a drive has been marked as failed, the vPOD will not double-
beep if a drive is marked as down, and the Mode Set button is held
down while powering-up the unit.
However, to clear this mode anyway, change the mode to Mode 0,
then back to the previous mode.
TABLE 5-6. Mode Set Button Functions
Indicator Description
Mode Set Button
(for Mode changes)
Used during the mode change procedure (see
p
age 5-12).
Press and hold this switch and apply power to the MV 4440. A double beep confirms
the mode change.
Release the switch after the double beep. The new Mode selection is now set.
Mode Set Button
(for drive rebuilds)
In RAID 6 mode, and when a drive is marked as “down,” this switch is used to start
the drive rebuild process.
After the alarm has been muted, press and hold the Mode Set button until you hear
two beeps. The rebuild process has now started.
See the “Audible Alarm” section and the “vPOD Hot-Swap Procedure
(in
Chapter 8, Maintenance) for additional information.