VP-747 Communication Protocol
40
11 VP-747 Communication Protocol
This section includes the Communication Protocol for the VP-747:
Communication Confirm:
Send CR
Reply CR>
Set Command
Send YControl_TypeFunctionParamCR
Reply ZControl_TypeFunctionParamCR>
Get Command
Send YControl_TypeFunctionCR
Reply ZControl_TypeFunctionParamCR>
Example: set Preview Source Type of Current Channel = RGBHV
Send Y0430CR
Reply Z0430CR>
Example: get Preview Source Type of Current Channel
Send Y143CR
Reply Z1430CR >
: ASCII Code 0x20
CR : Ascii Code 0x0D
After set type Command setting, the system will respond with a string.
Baud rate: 9600/115200bps, Data Bit: 8Bit, Parity: None, and Stop Bit: 1Bit.
Table 14 defines the Set Commands: