Kramer Electronics VP-747 Home Theater Screen User Manual


 
VP-747 Communication Protocol
45
45
Control Type Function Param1
Param2 Param3 Param4 Description
Set Get
0 1 91 32 ~ (HS-48) - - -
Preview Input
Setting User
Mode HW
0 1 92 80~(HT-HA-12) - - -
Preview Input
Setting User
Mode HS
0 1 93
640~1920
<= (HT-92)
- - -
Preview Input
Setting User
Mode HA
0 1 94
0: -
1: +
- - -
Preview Input
Setting User
Mode HP
0 1 95 384~2047 - - -
Preview Input
Setting User
Mode VT
0 1 96 2~(HS-13) - - -
Preview Input
Setting User
Mode VW
0 1 97 15~(VT-VA-1) - - -
Preview Input
Setting User
Mode VS
0 1 98
480~1200
<= (VT-16)
- - -
Preview Input
Setting User
Mode VA
0 1 99
0: -
1: +
- - -
Preview Input
Setting User
Mode VP
0 1 100
25 ~ 165 (Integer
Value)
0 ~ 999
(Decimal Value)
- -
Preview Input
Setting User
Mode OCLK
0 1 101
0:Off
1:On
- - -
Preview Input
Setting Enable
0 - 102 - - - -
Preview Input
Setting User
Mode Save
0 1 103
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
- - -
Preview Custom
Output Target
0 1 104 512 ~ 3071 - - -
Preview Output
Setting User
Mode HT
0 1 105 32 ~ (HS-48) - - -
Preview Output
Setting User
Mode HW
0 1 106 80~(HT-HA-12) - - -
Preview Output
Setting User
Mode HS
0 1 107 640 ~ 1920 - - -
Preview Output
Setting User
Mode HA
0 1 108
0: -
1: +
- - -
Preview Output
Setting User
Mode HP
0 1 109 384~2047 - - -
Preview Output
Setting User
Mode VT
0 1 110 2~(HS-13) - - -
Preview Output
Setting User
Mode VW
0 1 111
15~(VT-VA-1)
- - -
Preview Output
Setting User
Mode VS