Kramer Electronics VP-747 Home Theater Screen User Manual


 
KRAMER: SIMPLE CREATIVE TECHNOLOGY
VP-747 Communication Protocol
50
Control Type Function Param1
Param2 Param3 Param4 Description
Set Get
0 1 208 -100 ~ 100 - - -
Program Yellow
Saturation
0 1 209
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
- - -
Program Custom
Input Target
0 1 210 512~3071 - - -
Program Input
Setting User
Mode HT
0 1 211 32~(HS-48) - - -
Program Input
Setting User
Mode HW
0 1 212 80~(HT-HA-12) - - -
Program Input
Setting User
Mode HS
0 1 213
640~1920
<= (HT-92)
- - -
Program Input
Setting User
Mode HA
0 1 214
0: -
1: +
- - -
Program Input
Setting User
Mode HP
0 1 215 384~2047 - - -
Program Input
Setting User
Mode VT
0 1 216 2~(HS-13) - - -
Program Input
Setting User
Mode VW
0 1 217 15~(VT-VA-1) - - -
Program Input
Setting User
Mode VS
0 1 218
480~1200
<= (VT-16)
- - -
Program Input
Setting User
Mode VA
0 1 219
0: -
1: +
- - -
Program Input
Setting User
Mode VP
0 1 220
25 ~ 165 (Integer
Value)
0 ~ 999
(Decimal Value)
- -
Program Input
Setting User
Mode OCLK
0 1 221
0: Off
1: On
- - -
Program Input
Setting Enable
0 - 222 - - - -
Program Input
Setting User
Mode Save
0 1 223
0: Custom 1
1: Custom 2
2: Custom 3
3: Custom 4
Program Custom
Output Target
0 1 224 512~3071 - - -
Program Output
Setting User
Mode HT
0 1 225 32~(HS-48) - - -
Program Output
Setting User
Mode HW
0 1 226 80~(HT-HA-12) - - -
Program Output
Setting User
Mode HS
0 1 227
640~1920
<= (HT-92)
- - -
Program Output
Setting User
Mode HA
0 1 228
0: -
1: +
- - -
Program Output
Setting User
Mode HP