Maxtor SLD240 DVR User Manual


 
32
AUDIO:
This option determines the way to record sound if necessary.
ON: Enables AUDIO recording.
OFF: Disables AUDIO recording.
NOTE: Audio function can only be activated in the following refresh rates: 20, 12, 5.5, 2.4,
1.22, 0.71 fields/sec
MULTIPLEXER:
For optimum image recording, please set this option to ON when the DVR is connected to a
multiplexer for use. Set this option to OFF when it is only connected to a single camera or Quad
processor.
Note: For multiplexer (MUX) setup, refer to Section 4.1.1
5.2 ALARM SETTING
This menu allows users to program the configuration of alarm recording only when an alarm input is
activated. The device will record as long as the alarm input is activated.
ALM OPERATION:
This option determines whether to activate/deactivate the alarm recording when it detects an alarm input.
ON: The device activates the alarm recording when it detects an alarm input.
OFF: The device ignores the alarm signal when it detects an alarm input.
REC RATE:
This option is for the purpose of adjusting the number of pictures recorded per second onto a hard disk
when an alarm input is activated. There are 5 different record speeds you can select from: 60F/S (60
fields per second), 30F/S, 20F/S, 12 F/S, and REMAIN. If you select REMAIN for use, the device will
record images at the same speed as set on the REC page.
MAIN MENU
RECORD
ALARM
CLOCK / TIMER
COMMUNICATION
DISK
SYSTEM
GOTO ALARM PAGE
ALARM SETTING
ALM OPERATION : OFF
REC RATE : 20F/S
REC QUALITY : BEST
AUDIO : OFF
ALM TYPE : NO
ALM DURATION : 0 SEC
PRE- ALARM : OFF
MOTION SETTING
MAIN PAGE
ALARM REC ENABLE