14 C662M-E (5/03)
Figure 3. DX9000 System Connections (SCSI)
WARNING: The SCSI cables that connect the storage unit to the recorder are sensitive in nature. DO NOT tie them together in
any way. Doing so may damage the cables and render the system inoperable. These cables must hang loosely in the rack.
POWER
CONNECTION
37-PIN
CONNECTOR
8 COAXIAL CABLES
WITH BNC
CONNECTORS
PATCH PANEL
100BASET ETHERNET INTERFACE:
ALLOWS MULTIPLE VIEWSTATIONS
AND RECORDERS
POWER
CONNECTION
POWER
CONNECTION
POWER
CONNECTION
MINIMUM 8 CAMERA INPUTS
MAXIMUM 40 CAMERA INPUTS
STORAGE UNIT
RECORDER
VIEWSTATION
NOTE: A MAXIMUM OF FOUR SCSI
NOTE: EACH COAXIAL CABLE HAS A
NUMBER (1-8). THE NUMBERS ON THE
CABLES MUST MATCH THE NUMBERS
ON THE PATCH PANEL. FOR EXAMPLE,
EACH COAXIAL CABLE WITH A "1"
MUST MATCH NUMBERS 1, 9, 17, 25,
AND 33 ON THE PATCH PANEL.
STORAGE UNITS CAN BE CONNECTED
TO THE RECORDER. THE STORAGE UNIT
SHOWN IS CONNECTED TO THE
CONNECTOR LABELED “0” ON THE
RECORDER. A SECOND STORAGE UNIT
MUST BE CONNECTED TO THE
CONNECTOR LABELED “1.”
SCSI CABLE
RJ-45 STRAIGHT