Pelco DX3116 DVR User Manual


 
26 C695M-B (11/03)
MOTION
SENSITIVITY Specify the level of motion that is required to record captured images. This level is in
increments of 10 on a scale of 0 (minimum) to 100 (maximum). The default is 100.
At maximum sensitivity (100), motion detection is actually not used. The unit records all
images from the channel; it does not skip any images.
The DX3100 evaluates each image to identify the amount of change from the previous image.
If the amount of change is above the threshold, the unit records the image. If the amount of
change is below the threshold, the unit skips the image.
PTZ RX ADDRESS Specify the PTZ RX address that is configured for this camera. The default is 00, which means
none specified.
BRIGHTNESS Specify the brightness level for this channel. This setting ranges from 0 (minimum) to 100
(maximum). The default is 50.
CONTRAST Specify the contrast level for this channel. This setting ranges from 0 (minimum) to 100
(maximum). The default is 50.
HUE Specify the hue level for this channel. This setting ranges from 0 (minimum) to 100
(maximum). The default is 50.
CHROMA-U
CHROMA-V Specify the color levels for this channel. These settings range from 0 (minimum) to 100
(maximum). The default is 50.