C4631M-A (8/10) 41
RELAY OUTPUT SETUP
You can configure how the relay output is controlled: alarm acknowledge or post-alarm time. The relay out OFF setting does not control the actual
alarm recording function. Turning off the relay output does not terminate the alarm recording mode.
• Relay Off:
– ALARM ACKNOWLEDGE: The relay output feature must be turned off manually.
– POST-ALARM TIME: Turns off the relay output feature automatically when the post-alarm time expires. This setting is configured
individually for each channel. For information about configuring post-alarm time, refer to Normal Record Mode on page 30.
• System Alarm Out: Sets the relay output to either off or on.
To set up the relay output:
1. From the Linking menu, click Output.
2. Click the boxes to enter their settings.
3. Click Close.
4. Click OK.