30
24P (23.98P) Mode Settings
Chapter 2 Preparations
14
Press the m/MARK2 button to select “23.98P”.
15
If you want to change the monitor output setting as
well, press the </IN button to return to the higher
level screen (the state of step 11). If you do not want
to change the monitor output setting, proceed to step
19.
16
Press the m/MARK2 button to select “23.9P
OUTPUT”.
17
Press the ,/OUT button.
The setting value appears.
18
Press the M/MARK1 or m/MARK2 button to select
one of the following.
23.98PsF: Output as 23.98P.
2-3 PULL DOWN: Output after pulldown conversion
to 59.94i.
19
Press the SET button.
A confirmation message appears.
20
Press the SET button to confirm the changes, or the
RESET button to cancel them.
If you have pressed the SET button, power the unit off
and on again to enable the changes.
Output Signals in 24P (23.98P) Mode
The following tables show the signals output by the unit
when “23.98PsF” and “2-3 PULL DOWN” are selected.
Output signals
Timecode display
Timecode in remote timecode mode
See the optional “9pin Manual ‘PDW Series PROTOCOL
OF REMOTE(9-pin) CONNECTOR’” for more
information about remote timecode mode.
SETUP MENU
OPERATIONAL FUNCTION
SYSTEM SEL
SYSTEM FREQ : 601
* 60I
50I
30P
25P
23.98P
SETUP MENU
OPERATIONAL FUNCTION
SYSTEM SEL
23.9P OUTPUT: PsF
* 23.98PsF
2-3 PULL DOWN
Output Type 23.98PsF 2-3 PULL
DOWN
Output
signals
Composite
output
No output Video and
audio signals
pulled down to
59.94i
i.LINK DV
output
i.LINK TS
output
Timecode
output
COMPOSITE
VITC output
30-frame
timecode after
pulldown
conversion
Type 23.98PsF 2-3 PULL DOWN
LTC display 24-frame timecode
PDT display 30-frame timecode
after pulldown
conversion
VITC display 24-frame timecode
COUNTER display 24-frame signals 30-frame signals
after pulldown
conversion
Type 23.98PsF 2-3 PULL DOWN
9-pin preset
timecode
24-frame timecode
9-pin preset
timer 1 (Counter)
24-frame signals 30-frame signals
after pulldown
conversion
9-pin scene
timecode
24-frame timecode 30-frame timecode
after pulldown
conversion
9-pin scene
timer 1 (Counter)
24-frame signals 30-frame signals
after pulldown
conversion