Installing the Equipment
Page 2-22 Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
ST.TM.E10076.3
2.8 Setting the Encoder IP Address
2.8.1 Methods of Changing the Encoder IP Address
If, for any reason, the IP address has to be changed, this can be achieved
via the front panel menus (see Section 4.7.4 Remote Control Menu) or by
Telnet (see Section 2.8.3, Via Telnet). The user may also set the network
mask.
NOTE…
The new IP address is only accepted after the Encoder is repowered.
2.8.2 From the Front Panel Menus
To access the IP Address option from the front panel menus, press the IP
Address softkey in the Remote Control Menu. Edit the IP address via the
keypad and then press the Enter softkey.
IP Address
¬ Left Encoder IP Address : +
® Right `172.16.248.91’ —
O Enter l
O Update using softkeys Quit l
2.8.3 Via Telnet
A Telnet program is supplied with Microsoft Windows. To communicate
with the Encoder through Telnet:
1. From DOS, type telnet <IP address>.
2. Press Enter for the user name, and press Enter for the password.
3. The Main Telnet Menu is displayed.
Figure 2.9: Main Telnet Menu
4. Press <a> System, <b> Remote Control, <a> IP Address.
5. Enter the new value and press Enter.
6. Reset the Encoder.