Chapter 2 Installing the SPARC Enterprise T5120 and T5220 Servers 25
Installing the Cable Management Arm
for Both Servers
The rack mounting kit for each server comes with the same cable management arm
(CMA) assembly. The CMA installation and cable management procedures are the
same for both servers.
Note – The CMA includes velcro straps to secure the cables inside the CMA. Do not
install the velcro straps until you install the CMA, connect the cables, and place the
cabling inside the CMA as described in the following procedures.
▼ To Install the Cable Management Arm
Caution – Support the CMA during this installation. Do not allow the assembly to
hang by its own weight until it is secured by all three attachment points.
1. Remove the tape from the CMA rail extension (on the left of the CMA) and
remove the CMA rail extension.
2. Attach the CMA rail extension to rear left slide rail (
FIGURE 2-8).
At the rear of the rack, plug the CMA rail extension into the end of the left
sliding rail assembly. The tab at the front of the rail extension will click into
place.