48 SPARC Enterprise T5120 and T5220 Servers Installation Guide August 2007
2. Enter root for the login name followed by your password.
To Configure the Service Processor Network
Management Port
Note If your network allows the use of DHCP and SSH, this configuration is
performed automatically the first time you boot the system.
Use this procedure only when:
You are unable to use DHCP and SSH on your network.
You need to modify the ILOM service processor network management port
settings.
In this procedure, you connect to the ILOM service processor using the serial
management port to manually reconfigure the network management port.
Note For more information on configuring ILOM, refer to the Integrated Lights Out
Manager 2.0 Supplement for SPARC Enterprise T5120 and T5220 Servers.
Set these network parameters according to the specific details of your network
configuration:
/SP/network state – Specifies whether the service processor is on the network
or not
/SP/network pendingipaddress IP address of the service processor
...
hostname login: root
Password: password (nothing displayed)
Waiting for daemons to initialize...
Daemons ready
Sun(TM) Integrated Lights Out Manager
Version 2.0.0.0
Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
->