![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/2f/d2fc720f-fbe2-495b-aa40-fef22820ac8b/d2fc720f-fbe2-495b-aa40-fef22820ac8b-bg56.png)
60 SPARC Enterprise T5120 and T5220 Servers Installation Guide • August 2007
3. Using the ILOM CLI, type the stop /SYS command to perform a graceful
shutdown of the system.
Note – To perform an immediate and ungraceful shutdown, use the stop -force
-script /SYS or stop -script /SYS commands. These commands stop
everything immediately, ensure that all data is saved before entering these
commands.
4. Type the start /SYS command.
Note – To force a power on sequence, use the start -script /SYS command.
5. Reconnect to the system console with the start /SP/console command.
The systems displays various messages, followed by the ok prompt.
Verifying System Functionality
After powering on the system for the first time, you can use the Sun Validation Test
Suite (SunVTS™) software to verify the functionality and performance of any
installed components, as well as its network connections. Refer to the SunVTS
documentation at http://www.sun.com/documentation for more information.
-> stop /SYS
Are you sure you want to stop /SYS (y/n)? y
Stopping /SYS
->
-> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS
->
-> start /SP/console
Are you sure you want to start /SP/console (y/n)? y
Serial console started. To stop, type #.