Anritsu MP1777A Universal Remote User Manual


 
Section
8
Device Message Details
8.3.5
CALCulate Subsystem
The CALCulate subsystem performs the performance measurement setting and measured result display
:
CALCulate
-
:
DATA?
<string>
:
CALCulate
:
DATA? <string>
Command type Sequential command
Parameter
Response
<string>
=
<STRING PROGRAM DATA>
<string>
=
<STRING
RESPONSE DATA>
See the Table
8-1
for <string>.
Function Reads the measured results.
Example of use
>
:
CALCulate
:
DATA? "CURRent
:
JAMPlitude
:
PTPeak"
<
1.00
Table
8-1
String
Item
Jitter manual measurement
CURRent
Peak to Peak
+Peak
-Peak
RMS
LAST
Peak to Peak
+Peak
-Peak
RMS
<string>
"[CURRent:] JAMPIitude
:
PTPeak"
"[CURRent:l JAMPlitude
:
PPEak"
"[CURRent:] JAMPlitude
:
MPEak"
"[CURRent:] JAMPlitude
:
RhlS"
"LAST
:
JAMPlitude
:
PTPeak"
"LAST
:
JAMPlitude
:
PPEak"
"LAST
:
JAMPlitude
:
MPEak"
"LAST
:
JAMPlitude
:
RMS"
Response Format
Form
6
Form
6
Form
6
Form
6
Fom16
Form
6
Form
6
Form
6