Anritsu MP1777A Universal Remote User Manual


 
8.3
Device-Specific
Commands
:
SUORce
:
JlTTer
:
RANGe?
Command type
Response
Function
Restriction
Transmission sequential command
<range>
=
<CHARACTER RESPONSE DATA>
Makes a query of the transmission jitter generation range
Effective when jitter is generated.
Restrictions on setting apply depending on the Bit Rate.
Example of use
I
Bit Rate
/
UI
Ranae
I
I
SG
1
1.600.
SO,
0.5
UI
I
>
:
SOURce
:
JITTer
:
RANGe?
<
UI05
:
SUORce
:
JlTTer
:
AMPLitude?
Command type Sequential command
Response <string>
=
<STRING RESPONSE DATA>
Function Performs reading of the value of Tx JITTer AMPLitude.
Example of use
<
:
SOURce
:
JITTer
:
AMPLitude?
>
1.51