Anritsu MP1777A Universal Remote User Manual


 
A.l
Command Errors
Table
A-1
Error Messages of Command Errors
Code Messaae Error Detection Condition
-101
Invalid character
An invalid character is included in the header or the parameter.
Example: 1. A
#
is included in the header.
:
SENSe
:
TELecom
:
#RATe
MI39
2. A
$
is included in the parameter.
:
SENSe
:
TELecom
:
PATTem
:
TYPE PRB$
I
1
-104
Data type error
The parameter type is different to the type specified.
-105 GET not allowed
A
Group Execute Tngger was sent to the program message.
-
108 Parameter not allowed
The number of parameters is greater than the number specified.
Example: Four parameter have been sent to the Section where two param-
eters were originally specified.
:
SENSe
:
TELecom
:
DEMux
:
ROUTe M34,1,M8,2
-1
12
Program mnemonic too long
A program mnemonic
comes in 12 or more characters.
Example: A colon is missing from the header.
:
CALCulate
:
TELecom
:
PERFormanceTYPE G82
1
-
1
13 Undefined header
Although the header syntax
is
correct, it
is
not defined
by
the device.
Example:
The header was erroneously written.
:
SENSe
:
TELecom
:
DEMux
:
ROOT M34,l
-
120 Numeric data error
An error was found in the numeric data.
~-
-
-
121
Invalid character in number
An inappropriate character is included in the numeric data.
Example:
A
sign is included in the numeric data.
:
SENSe
:
TELecom
:
M3
:
MCHannel
3$
-
130 Suffix error
An error was found in the suffix.
Example:
A
part of data was set in alphabet while the parameter is numeric
data.
:
SENSe
:
TELecom
:
M2
:
MCHannel
31
-
144 Character data too long
The character data is more than 12 characters.
-
150
Str~ng data error
The string data comes outside the specified range.
Example: Single and double quotations are mixed.
:
DISPlay
:
MENU
:
NAME "SYSTem"