Anritsu MP1777A Universal Remote User Manual


 
8.3
Device-Specific Commands
8.3.1
INSTrument
Subsystem
The INSTrument subsystem is used to specify the same setting for the transmission and reception or independent setting
for each.
:
INSTrurnent
:
COUPle
<mode>
7
:
COUPle?
:
INSTrument
:
COUPle <mode>
Command type Sequential command
Parameter
Function
Restriction
<mode>
=
<CHARACTER PROGRAM DATA>
ALL
.............
Tx&Rx
(Same)
NONE
..........
Tx/Rx (Independent)
Specifies the selection of whether to establish the same setting for the transmission and
reception modules or independent setting for each.
When the mode is switched from
Tx/Rx to Tx&Rx, the set value for Rx is set for the Bit
Rate.
Example of use Sets the
same setting for the transmission and reception.
>
:
INSTrument
:
COUPle ALL
:
INSTrument
:
COUPle?
Command type Sequential command
Response <mode>
=
<CHARACTER RESPONSE DATA>
Same
as
:
INSTrument
:
COUPle
Function
Makes a query of whether the setting is the same for the transmission and reception
Example of use
>
:
INSTrument
:
COUPle?
<
ALL