50
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
2. Turn the JOG dial to display the desired device and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
3. Turn the JOG dial clockwise to move the reversed display
to the REMAIN HDD value and turn the SHUTTLE ring
clockwise.
• The background of the REMAIN HDD value turns red and
flashes.
4. Turn the JOG dial to display the desired capacity and turn
the SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
5. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦ CALL OUT SETTINGS
The CALL OUT setting is a setting to notify to the out-
side warning signals outputted by this device by
outputting the signals from the CALL OUT terminal on
the rear.
CALL OUT SETTINGS use photo-coupler output
to decrease the amount of malfunctions due to wiring.
See page 15 “CALL OUT Output terminal” for apt
connection procedures.
• HDD MAIN REMAIN/HDD SUB REMAIN
When the remaining memory in the HDD reaches the
set value, the unit outputs a signal from the CALL OUT
terminal, and the “REC/REM” warning displayed on the
screen.
<CALL OUT SETTINGS>
>>
HDD MAIN REMAIN OFF
HDD MAIN FULL OFF
HDD SUB REMAIN OFF
HDD SUB FULL OFF
“HDD SUB REMAIN” is appeared when
“PARTITION” is selected on “HDD SETTING” of the
<INITIALIZATION> screen.
Setting ( default : “OFF” )
“2%”, “4%”, “6%”, “8%”, “10%”, “15%”, “20%”, “30%”,
“40%”, “50%”, “OFF”
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMINAL SETTINGS>
}
Select “HDD MAIN REMAIN” or “HDD SUB REMAIN” in the
<CALL OUT SETTINGS> screen. Display the desired setting
and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
By pressing the WARNING RESET button, the HDD
capacity warning from the CALL OUT terminal can be
cancelled.
Setting ( default : “OFF” )
“REMAIN”, “WARNING”, “ALARM”, “OFF”
SETTING
BUZZER
When reaching the remaining
capacity set in “REMAIN HDD”
When a failure occurs and
a warning is displayed
When an alarm recording or
emergency recording is started
REMAIN
ON
OFF
OFF
WARNING
OFF
ON
OFF
ALARM
OFF
OFF
ON
OFF
OFF
OFF
OFF
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “BUZZER” in the <REAR
TERMINAL SETTINGS> screen. Display the desired setting
and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦ REMAIN HDD
A warning indicating that the either remaining capacity
of HDD has become low during recording is outputted.
The device can be selected and the remaining capacity
can be set here.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
MODE OUT 5 OFF
KEY SOUND ON
BUZZER OFF
>>
REMAIN HDD MAIN-10
%
CALL OUT SETTINGS
EMERGENCY REC DURATION 10M
A warning is outputted using the following methods
when the remaining capacity becomes low during re-
cording.
• The HDD usage display flashes when “3” is set to
“DISPLAY MODE” in the <TIME DATE/DISPLAY SET-
TINGS> screen.
• A buzzer will sound when “REMAIN” is set to “BUZZER”
in the <REAR TERMINAL SETTINGS> screen.
Setting of DEVICE ( default : “MAIN” )
“MAIN” : Displays a warning of low MAIN HDD capacity.
“SUB” : Displays a warning of low SUB HDD capacity.
“OFF” : Does not display warning of low capacity.
“SUB” is appeared when “PARTITION” is selected
on “HDD SETTING” of the <INITIALIZATION> screen.
Setting of “REMAIN HDD” ( default : “10%” )
“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”,
“40%”, “50%”
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
“Select “REMAIN HDD” in the <REAR
TERMINAL SETTINGS> screen and turn the SHUTTLE ring
clockwise twice.
• The setting display reverses in color when the SHUTTLE
ring is turned the first time. When the ring is turned for the
second time, the background turns red and flashes.
<INITIAL SET UP/INFORMATION> (continued)