Multi-Tech Systems RF310E Universal Remote User Manual


 
RASFinder RF300E/RF310E User Guide
RF300E/RF310E
178
S8 Pause Time for Comma
Unit: 1 second
Range: 0–65 (North America), 4–255 (International), 4–7(UK)
Default: 2 (North America), 4 (International and UK)
Determines the length of pause caused by a comma character in a dialing command. Default setting
is two seconds for North American model and four seconds for international and UK models. S8 can
be set for up to 65 seconds. S8 also defines the length of time the modem waits before retrying a call
after it detects a busy signal. Some computer systems need more than two seconds to reset. If this is
the case, increase the value of S8.
S10 Carrier Loss Disconnect Delay Time
Unit: 100 ms
Range: 1–254
Default: 20
Defines the length of time, in milliseconds, that the modem waits after a loss of carrier signal before
the it disconnects. The default setting is 2000 ms (20 units of 100 ms each). Maximum delay is 25400
milliseconds, or 25.4 seconds (decimal 254).
S11 Tone Dialing Spacing and Duration
Unit: 1 ms
Range: 50 - 150 (US) or 80–255 (Canada, UK, International)
Default: 95 (US) or 80 (Canada, UK, International)
Sets the speed of tone dialing (spacing and tone duration times). The default value is 95 units for
domestic models and 80 units for Canadian and International models, where each unit is one ms. In
other words, for domestic modems, each tone is sustained for 95 ms followed by a 95 ms pause. The
minimum S11 value allowed is 50 ms (50 units). The maximum S11 value is 150 ms (150 units).
S28 Enable / Disable V.34 Modulation
Unit: decimal
Range: 0, 1–255
Default:1 (enabled)
Enables or disables V.34 modulation. Setting S28 to zero (0) disables V.34 modulation. Any other
setting (1-255) enables V.34 modulation.
S35 Data Calling Tone
Unit: decimal
Range: 0–1
Default: 0 (disabled)
Enables or disables the V.25 data calling tone, which allows remote data, fax and voice
discrimination. Setting S35 to zero (0) disables V.25 data calling tone; setting S35 to 1 enables data
calling tone. The default setting is 1.
S37 Maximum Dial Line Rate
Unit: decimal
Range: 0–19
Default: 0
Sets the maximum dial line rate. When set to zero (0), the maximum dial line rate is the same as the
maximum modem speed. This is the most common setting and allows other modem functions to
actually determine the line rate used for each connection. It is the default. Consider using S37 to set
a maximum dial line rate if you need to artificially retain a lower modem speed.
0 = maximum modem speed 11 = 14400 bps
1 = reserved 12 = 16800 bps
2 = 1200/75 bps 13 = 19200 bps
5 = 1200 bps 14 = 21600 bps