WAN Port Setup
The WAN Port Setup dialog box controls how each WAN port is configured. The options at the top
of the dialog box (i.e., Port Enable, Needs Dial Backup, and the Scripting options) can be assigned to
each port listed in the Wans group in the lower right part of the dialog box. The Connection Method
can be set for either Answering or Dialing for each port listed in the Wans group. When the dialing
option is selected, the Asynchronous Gateway Server [AG Server] and Terminal Server groups
become inactive. To configure a WAN port for dial backup, you need to click on the Needs Dial
Backup option and then click on the Backup Port tab and enter the call back phone number, WAN
port, and priority of the call.
If a WAN port Needs Dial Backup in case it loses carrier (i.e., the Carrier signal, DCD, goes down),
then Wan 6 is dedicated for this purpose. Therefore, five of the six WAN port can be used for dial
backup. When the Needs Dial Backup option is selected, the call back number needs to be enterred
in the Dial Number field of the Backup Parameters. The WAN port number has to be specified and
the priority of the call back has to be specified. The call back priority ranges from No Priority to four.
The Script button provides access to the scripting options. The Script Dialog menu enables you to
edit, compile and download scripts. A script file (a text file containing a sequence of commands; refer