Panasonic AJ-HD150 VCR User Manual


 
89
SERVO CONTROL
ERROR
Counter display Description
VTR operation
(Restart condition)
REEL DIR UNMATCH
If the reel motor at the take-up side is running in the
reverse direction, the AUTO OFF lamp lights, and the
message display flashes.
STOP
(POWER OFFON)
REEL TENSION ERROR
SERVO COMM ERROR
SERVO ERROR
S-FF/REW TIMEOVER
S REEL ROTA TOO
FAST
T REEL ROTA TOO
FAST
T REEL TORQUE
ERROR
UNLOAD ERROR
S REEL TORQUE
ERROR
WINDUP ERROR
If an abnormal tension at the supply side is detected
in the reel mode, the AUTO OFF lamp lights, and the
message display flashes.
STOP
(POWER OFFON)
When the servo microcomputer does not follow the
instructions of the system control microcomputer even
when 10 seconds have elapsed, the AUTO OFF lamp
lights, and the message display flashes.
STOP
(POWER OFFON)
When there is no response from the servo micro-
computer for 1 or more seconds, the AUTO OFF
lamp lights, and the message display flashes.
STOP
(POWER OFFON)
When only the servo microcomputer was reset in an
instantaneous power failure, the AUTO OFF lamp
lights, and the message display flashes.
STOP
(POWER OFFON)
If the start/end processing operation is not completed,
the AUTO OFF lamp lights, and the message display
flashes.
STOP
(POWER OFFON)
If the supply reel motor should rotate at an abnormally
fast rate, the AUTO OFF lamp lights, and the message
display flashes.
STOP
(POWER OFFON)
If an abnormal torque applied to the supply reel motor
is detected or if an abnormal current flowing to the
current-sensing resistor is detected, the AUTO OFF
lamp lights, and the message display flashes.
STOP
(POWER OFFON)
If the take-up reel motor should rotate at an ab-
normally fast rate, the AUTO OFF lamp lights, and
the message display flashes.
STOP
(POWER OFFON)
If an abnormal torque applied to the take-up reel
motor is detected, the AUTO OFF lamp lights, and
the message display flashes.
STOP
(POWER OFFON)
If the tape has not been wound up during unloading,
the AUTO OFF lamp lights, and the message display
flashes.
STOP
(POWER OFFON)
If, after the total tape amount has been detected, the
amount of tape wound up on the take-up reel and the
amount of tape supplied by the supply reel differ to an
abnormal extent while the tape is traveling in the
forward or reverse direction, the AUTO OFF lamp
lights, and the message display flashes.
STOP
(POWER OFFON)
WINDUP REEL NOT
ROTA
If, after the cassette has been inserted, the tape take-
up reel has not wound up the tape while the total tape
amount is not detected and while the tape is traveling
in the forward or reverse direction, the AUTO OFF
lamp lights, and the message display flashes.
STOP
(POWER OFFON)
Monitor display
SERVO CONTROL
ERR
REEL DIR UNMATCH
REEL TENSION ERROR
SERVO COMM ERROR
SERVO ERROR
S-FF/REW TIMEOVER
S REEL TOO FAST
T REEL TOO FAST
T REEL TORQUE
ERR
UNLOAD ERROR
S REEL TORQUE
ERR
WINDUP ERROR
W-UP REEL NOT ROTA
Table of AUTO OFF Error messages