Panasonic PT-DS20KE Home Theater Screen User Manual


 
Maintenance/replacement
ENGLISH - 147
Maintenance
3) Attach the replacement lter unit optional accessory (Model No.: ET-EMF510) to the
projector.
z
The air lter unit has no difference between top and bottom, but is two-sided. Match the protrusion position
of the air lter with the grooves on the projector body.
z
Hook the air lter unit frame at the exhaust port side to the two tabs of the back side of the projector’s air
lter unit compartment and perform Step 2) in the reverse order to attach.
• Conrm that the tabs of the air lter unit compartment of the projector body are hooked to the air lter unit
frame.
Tabs on the projector body
Tabs on the projector body
Protrusion of the air filter unit
Protrusion of the air filter unit
Groove on the projector body
Groove on the projector body
4) Attach the air lter cover to the projector and use a Phillips screwdriver to tighten
the air lter cover screw.
z
Perform Step 1) in the reverse order.
Attention
z
When switching on the projector, make sure that the air lter unit is installed. If it is not properly attached, the
projector will suck in dirt and dust causing a malfunction.

If you use the projector without attaching the air lter unit, the message appears on the projection screen for
approximately 30 seconds.
Note
z
The replacement cycle of the air lter unit varies greatly depending on the usage environment.
Lamp unit
The lamp unit is a consumable component. See “When to replace the lamp unit” (
page 148) for details about
the replacement cycle.
Consult your dealer to purchase a replacement lamp unit (Model No.: ET-LAD510 (1 bulb), ET-LAD510F (4 bulbs)).
It is recommended that you request a qualied technician to replace the lamp unit. Consult your dealer.
Attention
z
Do not replace the lamp unit when it is hot. (Wait at least one hour after use.)
Checking the lamp unit to be replaced
Check the status of the lamp indicators <LAMP1>/<LAMP2>/<LAMP3>/<LAMP4>.
z
The lamp unit corresponding to the lamp indicator that is lit in red is required to be replaced.
Notes on the replacement of the lamp unit
z
A Phillips screwdriver is necessary when replacing the lamp unit.
z
Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.
Please handle with care.
z
Do not disassemble or modify the lamp unit.
z
When replacing the lamp unit, be sure to hold it by the handle because its surface is pointed and its shape
is protruded.
z
The lamp may be burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not
scatter. When the projector is mounted on the ceiling, do not make the replacement directly under the lamp
unit or put your face near it.
z
The lamp contains mercury. When disposing of used lamp units, contact your local authorities or dealer for
correct methods of disposal.
Attention
z
Use only specied lamp units.
Note
z
The model numbers of accessories and optional components are subject to change without notice.