Item
F1 (V.PROC)
F2 (VIDEO)
F3 (CHROMA)
F4 (HUE) (525-
line mode)/
(C PHAS) (625-
line mode)
F5 (SETUP)
(525-line mode)/
(BLACK) (625-
line mode)
F6 (YC DLY)
(DVW-M2000/
M2000P only)
Setting
Selects the control method for the internal digital video processor.
LOCAL: Change the settings of the internal digital video processor by using this function menu.
REMOTE: Use the optional BVR-50/50P Remote Control Unit to control the internal digital video
processor.
MENU: Change the settings of the internal digital video processor by using the MENU of the HOME page.
Sets the video signal output level (– to +3 dB).
PRESET: Regardless of manually values, the video signal is set to the standard level.
Manual setting: With the displayed setting flashing, you can rotate the MULTI CONTROL knob to adjust
the value for the video signal output level.
Sets the chroma signal output level (– to +3 dB).
PRESET: Regardless of manually set values, the chroma signal is set to the standard level.
Manual setting: With the displayed setting flashing, you can rotate the MULTI CONTROL knob to adjust
the value for the chroma signal output level.
Sets the color phase (phase relative to burst)
PRESET: Regardless of manually set values, the color phase is set to the standard value.
Manual setting: With the displayed setting flashing, you can rotate the MULTI CONTROL knob to adjust
the value across the range ±30°.
Sets the setup level (525/60 mode) or black level (625/50 mode)
PRESET: Regardless of manually set values, the level is set to the standard value.
Manual setting: With the displayed setting flashing, you can rotate the MULTI CONTROL knob to adjust
the setup level across the range ±30 IRE (525/60 mode) or to adjust the black level across the range
±210 mV (625/50 mode).
Sets amount of Y/C delay.
PRESET: Regardless of manually set values, the Y/C delay is to the standard value.
Manual setting: With the displayed setting flashing, you can rotate the MULTI CONTROL knob to adjust
the Y/C delay across the range ±100 ns.