14-5 Regular Checks
Chapter 14 Maintenance and Inspection
14-6 Chapter 14 Maintenance and Inspection
Component
Digital hours meter indication
(menu number in parenthesis)
Guideline replacement intervals
R: Replace C: Check, and replace if necessary
1000 hrs 2000 hrs 3000 hrs 4000 hrs 5000 hrs 6000 hrs
R (Replace at interval of
4000 hours.)
14-5-2 Maintenance Timings
Note that an arrow in the table means that the
component to be replaced is part of the assembly the
arrow points to, which must be replaced as a whole.
For information on severe conditions (frequent threading/
unthreading) or how to replace components, refer to the
Maintenance Manual Volume 1.
Use the following table as a timing guide for checking
and replacing components of the unit.
These intervals are not guaranteed lifetimes; the timing
for replacing components depends on the particular
conditions of use. In particular, depending on the
degree of dirt contamination and abrasion, pinch
rollers and cleaners may require replacement earlier
than suggested by this table.
Upper drum
Drum assembly
Brush slip ring assembly
Video head cleaner (roller)
Pinch roller assembly
Reel table assembly
Pinch application
assembly
Fan motor (card)
Fan motor (MD)
Power supply unit
Drum running time (H02)
Tape running time (H03)
Tape running time (H03)
Operation time (H01)
CCCC(↓)
C
RR(↑)
RR
RR
R
Replace after 40,000 hours
Replace after 40,000 hours
Replace after 40,000 hours