Sony KDL-40V2000 Flat Panel Television User Manual


 
TechLore
Understanding Sony Television Blinking Codes
Many of the later model Sony TV’s have a built in self-diagnosis function. If the timer/standby indicator is blinking,
this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action
required by you to engage it.
The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of
a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again.
Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses
are those, which you will see for each of these faults on a diagnosis screen described later in this article.
Intermittent problems? This is a great feature. You can also bring up these fault codes on-screen to see a list of the problem numbers with the
abbreviation of the problem and the number of times this problem has occurred. This is slightly different than entering the service mode. To
see the diagnostic screen, press the following buttons: Display, Channel, 5, volume Minus, ( not plus ) then Power. This brings up a screen with
a list of the problems and number of times they have occurred. Each of the problems named, are abbreviated as, "OCP", "OVP", "V STOP",
ETC. We have repeated them in parentheses in the text for the "Blinks" described above so you can correlate between the diagnostic screen and
the blink codes.
Now that you know about these self-diagnostics, how do you use them? Say that you have a set with a black screen. You see that the LED is
blinking four times. This would tell you that you have no vertical sweep, which is why the video is muted. If it was blinking 6 times, you would
know that you have a horizontal fault. It's not a sure cure..
IMPORTANT: After you repair the unit, you MUST clear the values on this diagnostic screen. These codes do not reset themselves after the
fault is corrected, so if you don't clear them, you'll be seeing "old" fault codes the next time you enter this screen. Clearing is done by going into
the service mode (display, channel, 5, volume plus, then power ). Press 8 and Enter, which returns everything to the factory preset condition.
Discussion:
adjam on November 10, 2006 3:55 AM
hi, might be I'm missing something, but would greatly appreciate a bit more info. I have a kf 42sx300 which was repaired last year and I saw
this diagnostic screen so I know the tele has it. However, the buttons you describe that need pressing do not appear on my remote,
specifically 'display' and 'channel'. Are they known by another name in the user guide?
thanx
Rich8988 on December 2, 2006 8:23 AM
by Larry Dillon October 27, 2006 12:15 PM
Posted in: Televisions and Projectors
Unit is dead, No
blinks
-
Problem in the standby power section. Might check fuse,
R607, Q601, IC601, R612 and
VDR601 (should show
open).
Continuous blink once a second, no pausing - No
reply from the jungle IC301 (data bus is busy, shorted to ground,
or held high), IK video path is defective.
One blink - not used for the self-diagnosis
Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2
blink fault. Could be a
short in the power supply of any of the circuits.
Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is
also a problem in the power supply circuit, check T603 and R672.
Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted.
Check IC1509, Q1505
Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the
self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on
the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen
slightly.
Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 &
516 and the jungle IC, IC206.
Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety
shutdown. Check power supply regulation and horizontal circuits.
Eight blinks
-
Problem with
the audio (AUDIO), unit goes to standby and blinks the self
-
diagnosis code.
Check IC406
audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback
transformer), or the associative components in the high voltage circuits are defective on the D board.
Nine blinks
-
Replace D 6116 and D 6301
on the "G" board, do not resolder as this will fix the problem temporary. Or
Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times
you get flashing, then change the
switching regulator on the "G" board or check connections. Make sure the regulator is -
12 or -13 (negitive).
Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors
are bad, check R8051 and IC8005, also on the "D" board.