Speco Technologies CS16 DVR User Manual


 
Operation Instruction
36
Highlight the LAN tab, and the LAN screen displays.
Figure 46 — LAN (Manual) setup screen.
Highlight the box beside Type and press the
button. You
can select the type of network configuration from: Manual,
DHCP and ADSL (with PPPoE). Select the desired type
and press the
button.
Selecting Manual from the Type allows you to set up LAN
parameters manually.
Change the numbers by highlighting them and using the Up
and Down arrow buttons to increase or decrease the number.
The factory default LAN settings are:
IP Address: 192.168.1.129
Gateway: 192.168.1.254
Subnet Mask: 255.255.255.0
NOTE:
Y
ou will need to get the appropriate IP Address, Gatewa
y
and Subnet Mask from your network administrator.
Highlight the box beside DNS Server. Press the Up and Down arrow buttons to set the IP address of the DNS server.
Highlight Use UPnP and press the button to toggle between On and Off. When it is On, port forwarding from the
NAT (Network Address Translation) device to the DVR will be enabled automatically via UPnP (Universal Plug and
Play) service. This function will be especially useful when accessing a port on a private IP address.
NOTE: For the UPnP service to work, the NAT device should support the UPnP Port Forwarding function and
the function should be set to enabled.
You cannot change the port settings when Use UPnP is On.
Highlight the Status box and press the button to display the port numbers forwarded from the NAT device via UPnP
service.
Highlight the Port Number Setup… box and press the button. The Port Number Setup screen appears.
NOTE:
Y
ou will need to get the appropriate Port Numbers for each Speco Central and Speco Remote related
program (Admin, Callback, Watch, Search and Audio) from your network administrator.
Change the numbers by highlighting them and using the Up and Down arrow
buttons to increase or decrease the number. The factory default Port settings are:
Remote Admin: 8200
Remote Callback: 8201
Remote Watch: 8016
Remote Search: 10019
Remote Audio: 8116
NOTE: Do NOT use the same port number for two different programs, otherwise, the DVR cannot be connected
with the PC running Speco Central or Speco Remote.
CAUTION: When changing the port settings, you must change the port settings on the PC running