StarTech.com SV11151PEXT Universal Remote User Manual


 
SV1115IPEXT and requires the use of a straight through serial cable.
Place the modem near the SV1115IPEXT and an available telephone jack. Connect the
modem to the telephone jack, data cable, and power source according to the instructions
in its documentation. The opposite end of the modem’s data cable should be a DB9
female serial connection. Connect that end of the cable to the DCE Serial connection on
the rear panel of the SV1115IPEXT.
Modem configuration
Although most connections will work appropriately with the default settings on
SV1115IPEXT, manual changes can be made. To do so:
Login to the Web interface as Admin. Click Modem, listed on the left side of the main
page. You will then be presented with the Modem Option menu (see above). Make the
following changes to enable and configure the modem connection.
Enable modem connections (PPP) via serial port/modem: select Enabled.
Baud rate to use (affects connection between us and the modem only): select
115200.
Init string: leave as ATE0S0=1&K3 (see below).
The baud rate dictates the connection speed between the SV1115IPEXT’s serial port
and the modem, and does not affect the connection speed between the local and remote
modems, as they will negotiate their own connection speed when a connection is made.
It is highly recommended that this setting be left at the default for best performance.
The initialization (“init”) string is the command (using the standardized Hayes AT
command set) that the SV1115IPEXT will send to the modem to activate it. The string
included should work with the majority of modems and configures the following
connection properties: answer incoming calls on the first ring, enable hardware flow
control, and lock the connection speed. Your modem’s documentation will describe other
potential init strings that you can use to alter the connection properties. For instance,
you could commit the settings to the modem’s non-volatile memory (NVRAM) or allow
the modem to adjust the connection speed for greater stability (and so on). You may
wish to test the connection with the default init string first, before making changes
specific to your modem model or situation, to simplify the troubleshooting process.
Instruction Manual
36
Rear Panel (DCE Serial port)
Front Panel (DTE Serial port)