2–Pump 12-Station Controllers Chapter 8: Service Only Information 58
SET RAMP DOWN TIME?
NO/YES
RAMP DN DLY: 8.000s
SETTING FOR PUMP n
SELECT PUMP 1 OR 2
USE KEYPAD TO ENTER
Setting the Ramp Down Time
Ramp down time is a delay that allows the pump to come to a full stop when needed. The
control cannot restart until this delay is completed. This is also known as the Shutdown delay.
This delay defaults to 8.0 seconds and should not be altered unless instructed to do so by
the Service Department.
At the above message prompt:
1. Press the YES key to enter the Ramp Down Time menu.
2. Select the pump for altering ramp down time.
The following screen displays.
Using the keypad:
3. Enter the new time and press the ENTER key to save the new setting.