Sterling 882.00249.00 Home Theater Server User Manual


 
2–Pump 12-Station Controllers Chapter 8: Service Only Information 61
HI VAC SENSOR DELAY?
NO/YES
SELECT PUMP 1 OR 2
USE KEYPAD TO ENTER
HIVAC DELAY: 3.000s
SETTING FOR PUMP n
Setting the Hi Vacuum Sensor Delay
Hi vac sensor delay is the time that a high vacuum condition must exist before it is sensed by
the controller. This delay eliminates the annoying Hi Vacuum errors which self-clear or are
erroneous. This delay defaults to 3.0 seconds and should not be altered unless you are
instructed to do so by the Service Department.
At the above message prompt:
1. Press the YES key to enter the Hi Vacuum Sensor Delay Time menu.
At the above message prompt:
2. Select the pump for altering vacuum sensor delay.
The following screen displays:
Using the keypad:
3. Enter the new time and press the ENTER key to save the new setting.