2–Pump 12-Station Controllers Chapter 8: Service Only Information 63
HI VAC LOAD COUNT?
NO/YES
SELECT PUMP 1 OR 2
USE KEYPAD TO ENTER
HV LOAD CNT: 7
SETTING FOR PUMP n
Setting the Hi Vacuum Load Count
Hi vacuum load count sets the maximum number of loads on a station in a high vacuum
condition. If a station repeatedly experiences a high vacuum condition for the selected
number of loads without being cleared or attended to, it goes off line to prevent damage to
the conveying system. This parameter defaults to 7 loads and should not be altered unless
you are instructed to do so by the Service Department.
At the above message prompt:
1. Press the YES key to enter the Hi Vacuum Load Count menu.
At the above screen prompt:
2. Select the pump for altering the high vacuum load count.
The following screen displays.
Using the keypad:
3. Enter the new time and press the ENTER key to save the new setting.