Sterling 882.00249.00 Home Theater Server User Manual


 
2–Pump 12-Station Controllers Chapter 8: Service Only Information 65
OUTPUT CONTROL?
NO/YES
AUTOMATIC OR MANUAL?
N=AUTO Y=MANUAL
Output Control Menu
The Output Control menu gives you direct access to all 20 outputs of the controller. The
menu has two (2) modes: Manual and Automatic. Automatic mode cycles each output on and
off. Manual mode gives you access to each individual output.
At the above message prompt:
1. Press the YES key to enter the Output Control menu.
The following screen displays.
To start the automatic cycle:
Press the NO key.
To increase speed:
Press the START/STOP key.
To decrease speed:
Press the SET key.
To exit the Output Control menu and turn all outputs OFF:
2. Press the CLEAR key.
Caution! Automatically cycling outputs with the pump in Active mode can damage
the conveying system.
Caution! Do not perform this action unless directed to do so by the Service
Department.