2–Pump 12-Station Controllers Chapter 8: Service Only Information 66
OUTBNK0: 0000000000
OUTBNK1: 0000000000
To access the outputs manually, at the AUTOMATIC OR MANUAL? screen prompt:
1. Press the YES key.
The following screen displays.
A cursor displays on the screen.
To move the cursor left:
Press the 4 key.
To move the cursor right:
Press the 6 key.
To move the cursor up:
Press the 2 key.
To move the cursor down:
Press the 8 key.
To toggle output ON or OFF:
Press the START/STOP key.
To exit this menu:
2. Press the CLEAR key.
Caution! Enabling the Pump output without opening any sequence valves can cause
damage to the conveying system.
Caution! Do not perform this action unless directed to do so by the Service
Department.