TANDBERG TT1260 Satellite TV System User Manual


 
Preventive Maintenance and Fault-finding
Page 6-6 Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder
ST.TM.E10100.1
Table 6.1: Fuse Information
Item Specification
Fuse Single pole, fitted in live conductor in power input filter at rear of unit.
Fuse type 5 mm x 20 mm anti-surge (T) HBC, IEC127 (sheet v)
Fuse rating 1.6 A, 250 Vac
To replace the ac power fuse perform the following:
WARNING…
BEFORE REPLACING THE REAR PANEL FUSE, DISCONNECT THE EQUIPMENT FROM THE
SUPPLY. FAILURE TO DO THIS MAY EXPOSE HAZARDOUS VOLTAGES. UNPLUG THE
EQUIPMENT FROM THE LOCAL SUPPLY SOCKET.
1. Ensure that power is turned off and the power cable is disconnected
from the ac power inlet.
2. Ease out the fuse carrier by placing a small, flat-bladed screwdriver in
the notches at the sides of the carrier.
CAUTION...
When replacing the power input fuse, always ensure that a fuse of the correct type and rating is fitted.
Failure to do so results in inadequate protection.
3. Replace the fuse in the carrier.
4. Insert the fuse carrier back in the ac power inlet.
Figure 6.2: Fuse Carrier
If the replacement fuse also blows, do not continue. Disconnect the
equipment and contact TANDBERG Customer Services (see Preliminary
Pages) for advice.
A
C Power Inlet
Fuse Carrie
r
To access the fuse, ease out the notch
with a small flat-blade screwdriver.