5.3. Alarm Hold and Reset
The Alarm can be held or reset when "1. KEY" has been selected in the "Alarm Hold" setting, and is not
activated when "2. ALWAYS" has been selected. (Refer to p. 36 "Alarm hold.")
5.3.1. Holding the alarm
Press the Alarm Hold key.
The Alarm Hold indicator light will flash.
5.3.3. Resetting the alarm
Press the Alarm Reset key.
The Alarm Reset indicator light will extinguish, resetting the alarm state.
Note
The alarm cannot be reset when "2. LEVEL" has been selected in the Alarm Signal setting. The state of alarm
continues as long as an alarm signal input is received. (Refer to p. 35 "Alarm signal.")
5.3.2. Displaying alarm-activated camera images
Press the Alarm Hold key.
The Alarm Hold indicator light will extinguish, displaying the alerted camera image on the monitor in full-
screen format.
[When an alarm signal is received during Alarm Hold]
The Alarm Reset indicator light flashes while the "AL HOLD" indication is displayed on the monitor.
LCD screen
ALARM HOLD
Flashes
RESET HOLD RESET HOLD
Monitor screen
ALARM
RESET HOLD RESET HOLD
Monitor screen
0403
0201
RESET HOLD RESET HOLD
Monitor screen
(4-segment split-screen display)
AL HOLD
03
02
04
01
Flashes
RESET HOLD RESET HOLD