TOA Electronics C-RM500 Universal Remote User Manual


 
6.4.3. Contact
Sets the alarm contact output terminal's operation.
Note
Contacts can only be set when "MASTER" has been selected in the "Operation mode" setting. This setting
item is not displayed on the menu screen if "SLAVE" has been selected.
Step 1. Press the Menu key to display the menu screen.
Step 2. Tilt the joystick up or down to select "CONTACT" and confirm it with the SET key.
The setting content will appear on Line 2.
Step 3. Tilt the joystick left or right to select one of the following setting contents, and confirm it with the
SET key.
1. SELECTION CHANNEL Makes the contact corresponding to the channel number (camera number)
when each channel is selected for full-screen display.
Also, if the connection of a switcher with 16 or more input channels has
been set, the channel number selected for full-screen display is converted
into binary data, and contacts 1 – 16 are assigned bits 0 – 15.
2. ALARM Makes the contact corresponding to the alarm-activated channel number
(camera number) when the number of connected switcher inputs is 16 or
less and there is an alarm signal input to each channel.
Also, if 16 or more inputs are set, the last channel to receive an alarm
signal is converted into binary data, and contacts 1 – 16 are assigned bits
0 – 15. In the normal state, no contacts are enabled.
3. BOTH In the normal state, the contact corresponding to the channel number
(camera number) is made when each channel is selected for full-screen
display. In the alarm state, when an alarm signal is input, the contact
corresponding to the channel number is made.
26
CONTACT
1.SELECT CH
[Setting contents]
Notes
When "10. OTHER" has been selected in the "Switchers" settings, only "1. SELECTION CHANNEL" can be
set.
This selection is set to "2. ALARM" by the factory.