TOA Electronics C-RM500 Universal Remote User Manual


 
6.4.8. Initial screen
Sets the screen to be displayed immediately after the power is turned on.
Step 1. Press the Menu key to display the menu screen.
Step 2. Tilt the joystick up or down to select "INITIAL SCREEN," then confirm the selection with the SET key.
The setting will appear on Line 2.
Step 3. Tilt the joystick left or right to select one of the following settings, and confirm it with the SET key.
Note: The settings differ depending on the type of switcher connected to the system.
6.4.7. Buzzer
Sets whether or not to sound the buzzer when an alarm signal is received.
Step 1. Press the Menu key to display the menu screen.
Step 2. Tilt the joystick up or down to select "BUZZER," then confirm the selection with the SET key.
The setting is displayed on Line 2.
Step 3. Tilt the joystick left or right to select either of the following settings, and confirm it with the SET key.
30
BUZZER
1.ON
INITIAL SCREEN
1.FULL
Switcher Type Setting
Multi-Switcher 1. FULL (full screen)
2. SEQUENCE
3. 4-SEG SEQ (sequential 4-segment split-screen display)
4. 4-SEG (4-segment split-screen display)
5. 9-SEG
6. 10-SEG
7. 16-SEG
Notes
• Make sure that the selected setting is the same as that for the connected switcher.
• This selection is set to "3. 4-SEGMENT SEQ" by the factory.
Smart Switcher 1. FULL
2. SEQUENCE
Note: This selection is set to "SEQUENCE" by the factory.
Other switchers 1. FULL
[Setting contents]
[Setting contents]
Note: This selection is set to "1. ON" by the factory.
1. ON Sounds a buzzer when alarm is activated.
2. OFF Sounds no buzzer when alarm is activated.