TOA Electronics C-RM500 Universal Remote User Manual


 
6.4.20. Tour sequence
The Tour Sequence function switches multiple camera outputs in sequence at a set time interval. Merely
pressing the Sequence key permits up to 128 camera outputs to be displayed on the full screen in the order of
their set playback number. The camera number, position number and viewing time can be set for individual
playback numbers.
Step 1. Press the Menu key to display the menu screen.
Step 2. Tilt the joystick up or down to select "TOUR SEQ"
and confirm the selection with the SET key.
The unit will wait for the entry of "YES" (to use the
function) or "NO" (to not use the function).
(Set by the factory)
Step 3. Tilt the joystick to the left or right to select either
"YES" or "NO," and confirm the entry by pressing
the SET key.
The setting is displayed on Line 2 if "YES" is
selected, and the unit switched to Playback Number
Entry Waiting mode.
Note that when the camera number or the position
number is not programmed in advance, the " "
indication is displayed in place of the number.
Step 4. Enter the playback number using the numeric
keypad or by tilting the joystick to the left or right,
and confirm the entered number with the SET key.
Enter a number from 1 to 128.
The flashing cursor moves to the camera number.
Step 5. Enter the camera number with the numeric keypad,
and confirm the number with the SET key.
Enter a number from 1 to 999.
The flashing cursor moves to the position number.
Step 6. Enter the position number with the numeric keypad,
and confirm the number with the SET key.
Enter a number from 1 to 255.
Tip: Entering "0" will switch the screen to full-
screen display, and does not execute position
playback.
The flashing cursor moves to the rightmost viewing
interval selection indication on Line 2.
Step 7. Tilt the joystick to the left or right to select the
viewing interval: "3SEC," "10SEC," "15SEC,"
"20SEC," "30SEC," or "1MIN." (SEC: seconds,
MIN: minutes)
Step 8. Press the SET key to confirm the set interval.
The procedure returns to Step 4.
Step 9. Repeat Steps 4 – 8 to continue setting the playback
numbers.
Press the Clear key to return to the setting item
display.
[Deleting Settings]
After pressing the Alarm Reset key, press the SET key.
39
TOUR SEQ 1
CPT10SEC
TOUR SEQ 1
CPT10SEC
4
1
TOUR SEQYES
3
(Example)
(Example)
(Example)
(Example)
SET
TOUR SEQ 1
C 123 P T10SEC
5
2 0 0
SET
1 2 3
SET
TOUR SEQ 1
C 123 P200 T10SEC
6
SET
SET
TOUR SEQ 1
C 123 P200 T10SEC
7
8
UP
DOWN
RIGHTLEFT
UP
DOWN
RIGHTLEFT
or
No.
(Set by the factory)
TOUR SEQ NO