Chapter 4 Activating event-driven data exchanges 83
Activating an event-driven data exchange through workflow
Activating an event-driven data exchange
through workflow
You can enter a request for an event-driven data exchange from an active link or
filter. The active link or filter can either write a request directly in the Application
Pending form or run the
eiexfer utility. See BMC Remedy Action Request System
7.1.00 Workflow Objects for instructions on how to create active links or filters on
your AR System form.
-302
Request has not completed in time interval allowed.
The event-driven request has been submitted, and the Integration Engine
service has been notified to handle the request. The request has not
completed within the time interval allotted to check for a request. The
event-driven interface makes three attempts to check for the completion
status. Each request is tried after waiting the number of minutes in the -w
parameter specified in
eiexfer.
-401
Transfer failed when handled by EIE service.
The event-driven request is complete and the Integration Engine service
has returned an error indicating the data transfer failed. For detailed
information about the error, check the debug file associated with the data
exchange used in the data transfer.
Table 4-7: eiexfer completion code messages
ID Number Message