AMX G3 Universal Remote User Manual


 
6 Installing Touch Panels Color Active-Matrix LCD Touch Panels
1.48
1.79
.23
.125 MAX RADIUS
IN CORNERS
11.85
(FRAME)
11.40
12.60
CUTOUT
(FRAME)
6.88
6.00
6.50
.25
INSERTS AT LOCATIONS
OF #6-32 THREADED
SUGGEST INSTALLATION
FOUR #6-32 SCREWS.
UNIT INSTALLS WITH
SHOWN
INSTALLATION METHOD
INSTALLED AS SINGLE "DROP-IN"
FRAME AND LOW PROFILE BACKBOX
SURFACES (PODIUM, DESK ETC.). FACE
USE WHEN INSTALLING UNIT ON SOLID
ASSEMBLY.
2. Insert a flat head screwdriver into the release slot on the AXU-CV(/PB)s or
AXU-CA(/PB)’s bezel and remove the engraved overlay.
3. Place the AXU-CV(/PB) or AXU-CA(/PB) into the cutout and mark the screw
insert positions as shown in Figure 4.
4. Remove the AXU-CV(/PB) or AXU-CA(/PB) and drill four #6-32 insert holes.
Then, place a threaded insert into each hole.
5. Attach the data and power wiring to the AXU-CV(/PB) or AXU-CA(/PB). Refer
to Wiring the Touch Panels for wiring diagrams and pinout descriptions.
6. Fasten the AXU-CV(/PB) or AXU-CA(/PB) and low-profile back box to the
surface using the #6-32 machine screws supplied with the enclosure.
7. Insert the engraved overlay back into the bezel.
8. Connect the AXlink wiring to the AMX Central Controller, and RS-232 wiring
(optional) to the external RS-232 device. The AXU-CV(/PB) or AXU-CA(/PB)
will beep when you apply power.
Figure 5
AXU-CV(/PB) or AXU-
CA(/PB) and low-profile back
box cutout dimensions
Note
The CATP must always be
installed with the release slot
located at the bottom