Clover Electronics CDR 0440 DVR User Manual


 
25
for all channels.
(FRAME RATE, QUALITY, RECORDING, PRE REC, POST EVT REC)
FRAME RATE
Set the frame rate for the specified channel. The sum of the frame rate
values from each channel cannot exceed the maximum frame rates for a
specific recording resolution.
Typical values of the maximum frame rate for video are
120/100 fps version
120/100fps: 352*240(NTSC)/352*288(PAL)
60/50fps: 704*240(NTSC)/704*288(PAL)
30/25 fps: 704*480(NTSC)/704*576(PAL)
QUALITY
Select the recording quality for the specified channel. Options are:
Network, Standard, High, Superior and Ultra.
RECORDING
Assign the recording mode for each channel. Options are: Continuous, By
Motion, By Sensor, By Schedule or Disable.
ELECTRIC LIGHT
CONTROL
Enable/Disable electric light control. When alarm output is connected to an
electric light for the motion detection signal, user needs to set ELECTRIC
LIGHT CONTROL to ON. Then the motion detection signal will not be
activated for 2-3seconds after alarm output is turned off.
SENSOR RECORDING
Enable setting up to 4 sensors of 9 sensors for the specified channel using
the control button (
Ÿ ź).
PRE RECORD
Enable/disable pre-event recording. Pre-event recording time is 3 seconds
and only intra-frames are recorded for pre-event recording.
POST EVENT RECORD
Set the post event recording time duration for the specified channel. (10-
30 seconds)
AUDIO
Enable/disable audio recording for the specified channel.
z Fixed-available on only from channel 1 to channel 4.
SCHEDULE
Set the recording schedule. Press SEL to go to schedule setup screen.