A016-1CG-1.00-2 General
4
Full
Field Range Description
Comm Fail Timer 10 to 3600 The amount of time in seconds that the C3000/C0300 DPA waits to
receive an intelligible message from a master station before declaring
that communications have failed for the affected communication port.
This entry is ignored if the Fail Output option is Undefined (-1).
LRU Offset Indexes into
A016_XRF table.
The one based offset from the first entry in the A016_XRF table, which
corresponds to this port. The A016
_
XRF table is described in the next
chapter.
Total LRUs 1 to 32767 The number of LRUs communicating on this port. This entry is used in
conjunction with the XRF Offset entry to determine the exact range of
records in the A016
_
XRF table that this communication port is to utilize.
The high entry limit is confined to the number of records in the
A016_XRF table. Also the entered value, plus the XRF Offset entry, must
not exceed the number of records in the A016_XRF table.
Table 3. Character Times at the selected Baud Rate
Baud Rate One Character Time(ms)
110 91
300 34
600 17
1200 9
1800 6
2400 5
4800 3
7200 2