GE A016-1CG Cable Box User Manual


 
Custom ABB C3000/C0300 DPA
Configuration Guide
GE Power Systems
General A016-1CG-1.00-2
Full
31
ERR 2006: INVALID LRU COUNT, REC <xx>
Why:
The LRU Count entry for the indicated A016_COM record number is not within the valid
entry range described earlier in this document.
Remedy:
Modify and re-download the configuration with a correct entry in the specified configuration
record.
ERR 2007: INVALID OFFSET/COUNT, REC <xx>
Why:
The XRF Offset and LRU Count entries for the indicated A016_COM record number, in
combination, are not within the valid entry range described earlier in this document.
Remedy:
Modify and re-download the configuration with correct entries in the specified configuration
record.
ERR 2008: DUPLICATE LRU ADDRESS, REC <xx>
Why:
The LRU address for the indicated A016
_
XRF record number is the same as another one for
the same communications port. LRU addresses must be unique for all LRUs associated with
a communications port.
Remedy:
Modify and download the configuration with correct entries in the specified configuration
record.
ERR 2100: INVALID ADDRESS, REC <xx>
Why:
The LRU Address entry for the indicated A016_XRF record number is not within the valid
entry range described earlier in this document.
Remedy:
Modify and re-download the configuration with a correct entry in the specified configuration
record.