Manual Calibrations 4-5
◆ Double Lines — alternate method for use when a refer-
ence measuring stick is not available
8. Select one of the options and press the E (Menu In) key to
continue.
9. Follow the applicable procedure below.
34-Inch/12-inch Calibration
10. Press the B key to continue.
The printer asks whether you want to print the media feed
calibration.
11. Press the B key to continue.
The printer prints the calibration marks, and prompts you to
adjust the advance.
12. With a metal yardstick, measure the distance between the
marks.
A measuring stick with 1/64 inch markings works best.
13. Adjust the media feed advance using the control panel.
You can increase the advance by pressing the C key, or
decrease it by pressing the p key.
14. Press B (Proceed) to save the advance value you entered.
15. Press B (Proceed) to return to the menu.
Fig. 4-16. Media Feed Calibration pattern