36 C2602M-C (3/07)
Figure 38. Relay Output Setup Menu
3. For each alarm, modify the following relay settings:
• Select an alarm, and change its relay output to Enable or Disable.
• Change the relay mode to Latched or Transparent.
• For latched relays, select a duration. Durations can last as little as five seconds, as long as five minutes, or until an operator manually
turns off the relay with a key (Until Key-In).
4. Select the Relay Type field and set the relay to normally open (N/O) or normally closed (N/C).
5. After these settings are modified, press the Return button until all menus are cleared. A message appears stating that the settings are