Alarm Detection Setup
Off : Sensor does not operate.
N.O(Normal Open) Sensor : Sensor remains open all the time and if closed,
an alarm will be issued. (A Contact)
N.C(Normal Close) Sensor : Sensor remains closed all the time and if open,
an alarm will be issued. (B Contact)
Cam
It is used to set a camera that synchronizes with the current sensor. The default setting
follows the sensor number. A sensor can synchronize with multiple cameras so multiple
values can be selected. You can set a preset for each camera to synchronize sensors
with cameras. If a sensor triggers the corresponding camera, the camera can show you
the preset location.
Alarm-out
Sets the Alarm-Out when Alarm Sensor sounds.
5 Alarm Outs are supported un the present.
Choose an alarm-out that you want to synchronize with the current sensor.
Multi-selection is possible.
Duration
Sets the Alarm-Out Duration. Alarm-Out continues for the set value.
Off / 3sec / 5sec / 10sec / 20sec / 30sec / Continuous
SHR-2040/2041/2042-ENG-1013 10/19/07 10:23 AM Page 5-24