Quality
Quality will be determined.
Select the one among Very High / High / Standard / Low
Rate
Sets the Rate the number of screen recorded every second.
It you set to 15.00 ips, the system records too many screens per second and play continues
intermittently since recording is more detailed. This is appropriate for concentrated
monitoring zone setup.
In case of NTSC, select the one of 30.00 ips / 15.00 ips / 10.00 ips / 7.50 ips / 5.00 ips
/ 3.00 ips / 1.00 ips.
In case of PAL, select the one of 25.00 ips / 12.50 ips / 8.33 ips / 6.25 ips / 5.00 ips / 2.50 ips
/ 1.00 ips.
The Event Recording setup menu will be activated depending on Video On / Off in Camera
Setup (Menu5-12).
When the video size in the Camera Setup Menu is set to Half D1 and less than 2 cameras
are activated, the frame rate of recording may start from 30.00 ips(NTSC) / 25.00 ips(PAL)
and when the video size in the recording mode is set to Half D1 and more than 3 cameras
are activated, the frame rate of recording may start from 15.00 ips(NTSC) / 12.50 ips(PAL).
CIF supports from 30.00 ips(NTSC) / 25.00 ips(PAL) regardless of the number of activated
camera.
Pre-Event(PreEve)
Post-Event(PostEve)
Records the situation until Alarm is issued.
Off : No recording
5sec / 10sec / 20sec / 30sec : The recording time options before Alarm issue
Records the situation since Alarm is issued.
Off : No recording
5sec / 10sec / 20sec / 30sec / 1min / 3min / 5min / 10min / 20min : Sets the recording time after an event occurs.
Video size
The Video size is displayed at the bottom of left 5-19.
When changing to a 1-channel DVR, it only supports 30 ips in the Full D1 resolution.
Pre-Event Section
Event time
Post-Event Section
Event time